Get storm ready.
Surges resulting from severe weather can damage electrical circuits and your connected electronics and appliances. If you think your backup generator isn’t another source of power fluctuations and surges, think again.
Help safeguard your essentials from damage with Eaton’s surge protection devices. Our power inlet boxes help connect your home’s circuits to a portable generator, and our mechanical interlock kits enable a safe and reliable transfer to emergency power when you need it most.
| Catalog number | Amperage | What typical size generator is used with each amperage |
| EGSPIB20 | 20 A | 2–4 kW |
| EGSPIB30 | 30 A | 3–5 kW |
| EGSPIB50 | 50 A | 5–7 kW |
| Catalog number | Main breaker type | Type of Loadcenter needed | Warranty |
| BRPMIKCSR | CSR | BR PON | 10 year |
| BRPMIKBR | BR | BR PON | 10 year |
| BRMIKCSR | CSR | BR Legacy | 10 year |
| BRMIKBR | BR | BR Legacy | 10 year |
| CHPMIKCSR | CSR | CH PON | Limited Lifetime |
| CHPMIKCH | CH | CH PON | Limited Lifetime |
| CHMIKCSR | CSR | CH Legacy | Limited Lifetime |
| Catalog number | Amperage | Notes | Surge current capacity | Type of Loadcenter needed | Warranty |
| CHSPT2ULTRA | Requires dedicated 50 A breaker | External to panel, NEMA 4 | 108 kA | Any Eaton or other manufacturer panel | Limited Lifetime, $75,000 connected equipment |
| BR230SUR | 30 A breaker and whole home surge | Internal to panel | 36 kA | BR Legacy or PON | 5 year, $25,000 connected equipment |
| BR250SUR | 50 A breaker and whole home surge | Internal to panel | 36 kA | BR Legacy or PON | 5 year, $25,000 connected equipment |
| CHN230SUR | 30 A breaker and whole home surge | Internal to panel | 36 kA | CH Legacy or PON | 5 year, $25,000 connected equipment |
| CHN250SUR | 50 A breaker and whole home surge | Internal to panel | 36 kA | CH Legacy or PON | 5 year, $25,000 connected equipment |
| BRPSURGE | No breaker required, 2 spaces required in panel | 18 kA | BR PON | 1 year | |
| BRNSURGE | No breaker required, 2 spaces required in panel | 18 kA | BR Legacy | 1 year | |
| CHPSURGE | No breaker required, 2 spaces required in panel | 18 kA | CH PON | 1 year | |
| CHNSURGE | No breaker required, 2 spaces required in panel | 18 kA | CH Legacy | 1 year | |
| CLNSURGE | No breaker required, 2 spaces required in panel | 18 kA | Eaton or other manufacturer 1" panel | 1 year | |
| CHSPT2FLUSHMNT | Box required to flush mount CHSPT2ULTRA in sheet rock | ||||
| CHSPCABLE | Protects 2 quad shield cables, Raintight | 10 kA per line | Limited Lifetime, $10,000 connected equipment |
| Catalog number | Amperage | Color suffix | V/AC | NEMA | Maximum surge current | Description | Notes |
| TR5262__S-SP-L | 15 A | B, BK, BL, GY, LA, RD, V, W | 125 | 5-15R | 18 kA per mode | Commercial grade, duplex receptacle, TR | Receptacles w/audible alarm and LED indicators, back and side wire |
| TR5362__S | 20 A | B, BK, BL, GY, LA, RD, V, W | 125 | 5-20R | 18 kA per mode | Commercial grade, duplex receptacle, TR | Receptacles w/audible alarm and LED indicators, back and side wire |
| TR5260__S-SP-L | 15 A | B, BK, BL, GY, LA, RD, V, W | 125 | 5-15R | 18 kA per mode | Commercial grade, duplex receptacle, TR | Receptacles w/LED indicators, back and side wire |
| TR5360__S | 20 A | B, BK, BL, GY, LA, RD, V, W | 125 | 5-20R | 18 kA per mode | Commercial grade, duplex receptacle, TR | Receptacles w/LED indicators, back and side wire |