Download document () of 20
Hydraulic-Magnetic Circuit Breaker (HMCB)

Remote Breaker Reset (RBR) Series

Available for JS, AR, AP, GJ and GJ1P series, the Remote Breaker Reset complements some of our most versatile hydraulic-magnetic circuit breakers by remotely opening them via a pulse signal in case of nuisance tripping. Downtime can be greatly reduced, and space can be optimized by delocalizing the critical function. It is available in 3 sizes, can reset up to 4 poles and operates within a voltage range of 24 VDC to 110 VDC.

Featured applications: Telecom, rail, machine building, defense, medical, marine, entertainment

Series Features

  • Wide operating voltage (24-48-72-110 VDC): Supports a broad range of applications.
  • Front panel mounting: Simplifies installation and maintenance in compact spaces, utilizing only vertical space.
  • Available in 3 sizes: for mono and multipole circuit breakers.
  • Possible hot Reset: The speed of actuation allows a rapid closing of circuit breaker avoiding internal arcing and damages of contacts if circuit is powered.
  • Standalone ordering: More flexibility by enabling individual purchase for simplified ordering and stocking, without needing to bundle with the breaker.

RBR Series Benefits

  • Decrease total cost of ownership: Reduce downtime and service repair costs by controlling breakers remotely.
  • Function optimization: Optimize weight, size, and cost of the function by replacing contactors, motorized switches and protection devices with the RBR.
  • Increase comfort and convenience: Now that the function can be delocalized, more space is available to increase comfort and convenience.
  • Enhance revenue potential: Depending on the application, more space translates to more revenue. For rolling stock, increased seating space or passenger comfort can be maximized as critical functions are now placed into less-accessible places.
Specifications

Electrical characteristics

Operating voltage (VDC) 

Power Current (A)

ARJS-1

24 VDC (11.8 A)

72 VDC (4.6 A)

110 VDC (3.4 A)

 

ARJS-4

24 VDC (7.6 A)

48 VDC (3.9 A)

72 VDC (2.5 A)

110 VDC (1.9 A)

 

GJ-4

24 VDC (12.6 A)

Voltage

-30% to +25% of Un

Type of signal

Voltage pulse

Voltage

Min. 500 VAC (RBR rated 24 and 48 VDC) or

min. 1000 VAC (RBR rated 72 and 110 VDC)

Insulation resistance

>20 MOhm

Operating conditions

Operating temperature

-40°C to +70°C (-40°F to +158°F)

Endurance

Minimum 10’000 cycles

Voltage pulse duration on CMD

ARJS-1

0.2 to 0.8s

 

ARJS-4

0.8 to 2s

 

GJ-4

0.8 to 2s

Duty cycle of coil

ARJS-1

1% (3s out of 300s)

 

ARJS-4

5% (15s out of 300s)

 

GJ-4

5% (15s out of 300s)

Resting time between 2 pulses

30 seconds (recommended)

Self-protection against long pulse

ARJS-1

No

 

ARJS-4

Yes

 

GJ-4

Yes

Certifications and Approvals

Low temperature

EN 60068-2-1

Dry heat

EN 60068-2-2

Cyclic damp heat

EN 60068-2-30

Salt spray test

EN IEC 60068-2-11, test Ka (48 hours minimum)

Other approvals

Design conforms to EN 50121-3-2 (electromagnetic compatibility)

Approvals – Rail

Design conforms to EN 50155, IEC 61373 (Cat 1, class B), EN 45545-2 (HL3 R26)

Dimensions

Dimensions WxHxD

ARJS-1

19 x 60 x 20 mm (0.75" x 2.36" x 0.79")

 

ARJS-4

35 x 61.5 x 35 mm (1.38" x 2.42" x 1.38")

 

GJ-4

60 x 195 x 70 mm (2.36” x 7.68” x 2.75”)

Weight

ARJS-1

65 grams (0.14 lb)

 

ARJS-4

300 grams (0.66 lb)

 

GJ-4

2’100 grams (4.63 lb)

Mounting, Terminals

Mounting direction

Vertical

Mounting plate thickness

ARJS-1

1.5 to 2.5 mm (0.059" to 0.098")

 

ARJS-4

2.0 to 5.0 mm (0.079" to 0.197")

 

GJ-4

2.0 to 5.0 mm (0.079" to 0.197")

Power connection

ARJS-1

SMS 3 pin

 

ARJS-4

SMS 3 pin or Hirschmann 4 Faston

 

GJ-4

Flying leads